Transformation efficiency = Total number of cells growing on the agar plate/Amount of DNA spread on the agar plate (in μg)
Transformation efficiency = Total number of cells growing on the agar plate/Amount of DNA spread on the agar plate (in μg)
-
Refer to http://www.bio-rad.com/LifeScience/pdf/Bulletin_9563.pdf for protocl details.
+
Refer to [http://www.bio-rad.com/LifeScience/pdf/Bulletin_9563.pdf BioRad] for protocol details.
== <B>Circuit 1: Proof of Concept</B> ==
== <B>Circuit 1: Proof of Concept</B> ==
Line 308: Line 308:
<U>Re-suspending DNA</U><br>
<U>Re-suspending DNA</U><br>
Part BBa_J45200<br>
Part BBa_J45200<br>
 +
Part BBa_K145201<br>
Pipet<br>
Pipet<br>
Distilled Water<br>
Distilled Water<br>
Line 315: Line 316:
container for ice<br>
container for ice<br>
timer<br>
timer<br>
-
LB agar plate of BBa_J45999 patches
+
Agar stab BBa_J45999
-
LB agar plate of NEB10 beta strain (control) patches
+
Agar stab NEB10 beta strain (control cells)
<br>
<br>
2.0ml microcentrifuge tubes (kit)<br>
2.0ml microcentrifuge tubes (kit)<br>
Line 322: Line 323:
sterile inoculating loops (kit)<br>
sterile inoculating loops (kit)<br>
Part BBa_J45200<br>
Part BBa_J45200<br>
 +
BBa_K145201<br>
LB broth<br>
LB broth<br>
LB agar plates  (kit)<br>
LB agar plates  (kit)<br>
Line 332: Line 334:
<U>Streaking from agar stabs</U><br>
<U>Streaking from agar stabs</U><br>
1. Clean lab bench by wiping down with 70% ethanol and paper towels.<br>
1. Clean lab bench by wiping down with 70% ethanol and paper towels.<br>
-
2. Label an agar plate (ampicillin) with Indole Free or BBa_J45999.<br>
+
2. Label an LB agar plate Indole Free or BBa_J45999.<br>
3. Label an LB agar plate with NEB 10-beta.<br>
3. Label an LB agar plate with NEB 10-beta.<br>
-
4. Use an inoculating loop to transfer some cells from the agar stab to the plate. There is a hole in each agar stab from where it was inoculated. Dip an inoculating loop into the stab at the same location, and streak the bacteria onto the agar plate in a zig-zag pattern. Using a fresh inoculating loop, streak onto the agar plate again creating a new zig-zag pattern that overlaps the first. This will help ensure that you will have single colonies to pick from. Streak gently, and try not to puncture the agar.<br>
+
4. Use an inoculating loop to transfer some cells from the BBa_J45999 agar stab to the plate. There is a hole in each agar stab from where it was inoculated. Dip an inoculating loop into the stab at the same location, and streak the bacteria onto the agar plate in a zig-zag pattern. Using a fresh inoculating loop, streak onto the agar plate again creating a new zig-zag pattern that overlaps the first. This will help ensure that you will have single colonies to pick from. Streak gently, and try not to puncture the agar.<br>
5. Repeat step 4 for the NEB 10-beta strain.<br>
5. Repeat step 4 for the NEB 10-beta strain.<br>
6. Place the agar plates into the incubator upside down at 37°C for 14-16 hours or room temperature for 24-30 hours.<br>
6. Place the agar plates into the incubator upside down at 37°C for 14-16 hours or room temperature for 24-30 hours.<br>
7. After incubating they can be stored in a fridge at 4°C until a culture can be grown.
7. After incubating they can be stored in a fridge at 4°C until a culture can be grown.
-
<U>Growing up cell cultures</U><br>
+
<b>Transformation of Plasmid 1 (BBa_J45200)</B><br>
-
1. Clean the lab bench by wiping down with 70% ethanol and paper towels.<br>
+
<U>Preparing BBa_J45999 and NEB 10-beta cells (competent cells)</U>
-
2. Remove the agar plates from the incubator or fridge.<br>
+
-
3. Label one 14 mL culture tube for part J45999. Add 5 mL of LB broth (amp) to each culture tube.<br>
+
-
4. Use an inoculating loop to pick a single colonly from each agar plate and inoculate the LB broth. Press lightly on the snap cap of the 14 mL tube, the capes should be a bit loose to allow for air flow.<br>
+
-
5. Incubate for 16 hours at 37°C in a rotator or shaker. <br>
+
-
6. After incubation, the cell culture should be cloudy. You can now firmly press down on the snap caps to seal the tubes and store the cell culture at 4°C until you’re ready to move onto the next step.
+
-
<U>Preparing NEB 10-beta cells (competent cells)</U>
+
1. Remove the agar plate for NEB 10-beta from the incubator or 4°C fridge. <br>
-
1. Remove the agar plate for NEB 10-beta from the incubator of 4°C fridge. <br>
+
2. Label one Eppendorf tube with "NEB 10-beta" and add 100ul of distilled water to it.<br>
-
2. Label one 0.6ml tube with "NEB 10-beta" and add 100ul of distilled water to it.<br>
+
3. Use an inoculating loop, or pipette tip, to pick a single colony from the NEB 10-beta agar plate and inoculate the distilled water.<br>
3. Use an inoculating loop, or pipette tip, to pick a single colony from the NEB 10-beta agar plate and inoculate the distilled water.<br>
-
4. Pipette up and down to re-suspend the colony into the distilled water, and transfer to the fresh SOB agar plate.<br>
+
4. Pipette up and down to re-suspend the colony into the distilled water, and transfer to the fresh LB agar plate.<br>
5. Spread the cells across the plate using either an inoculating loop, or by pouring 3-6 glass beads into the plate, covering, and shaking from side to side.<br>
5. Spread the cells across the plate using either an inoculating loop, or by pouring 3-6 glass beads into the plate, covering, and shaking from side to side.<br>
-
6. Place the SOB agar plate into the incubator with the agar side facing up, lid facing down (see picture below). Incubate the plate at 37°C for 14-16 hours. Alternately, incubate at room temperature for 24-30 hours.<br>
+
6. Place the LB agar plate into the incubator with the agar side facing up, lid facing down (see picture below). Incubate the plate at 37°C for 14-16 hours. Alternately, incubate at room temperature for 24-30 hours.<br>
7. Once your agar plate has grown up you can store it in your fridge (4°C) until you're ready to make competent cells.
7. Once your agar plate has grown up you can store it in your fridge (4°C) until you're ready to make competent cells.
 +
8. Repeat for BBa_J45999 cells.
<U>Re-suspending </U><br>
<U>Re-suspending </U><br>
-
1. Use a pipette to re-suspend part J45200 with 10 microliters of distilled water. Aspirate up and down a few times to ensure the DNA has been fully re-suspended.  
+
1. Use a pipette to re-suspend part J45200 with 10 μl of distilled water. Aspirate up and down a few times to ensure the DNA has been fully re-suspended.  
<U>Transformation</U><br>
<U>Transformation</U><br>
-
1. Obtain a slant of Bba-J45999 indole free chassis.<br>
+
1. Obtain the prepared LB plates BBa_J45999 indole free chassis and NEB 10-beta prepared from the previous step.<br>
-
2. Label one closed micro test tube +J45200 and another -J45200. Place them in the foam tube rack.<br>
+
2. Label one closed microtube +J45200 and another -J45200. Place them in the foam tube rack.<br>
-
3. Open the tubes and, using a sterile transfer pipet, transfer 250 microliters of transformation solution (CaCl2).<br>
+
3. Open the tubes and, using a sterile transfer pipet, transfer 250 μl of transformation solution (CaCl2).<br>
4. Place the tubes on ice.<br>
4. Place the tubes on ice.<br>
-
5. Use a sterile loop to pick up a single colony of bacteria from the starter plate. Pick up the +J45200 tube and immerse the loop in the transformation solution at the bottom of the tube. Spin the loop between your index finger and thumb until the entire colony is dispersed in the transformation solution (with no floating chunks). Place the tubes back in the tube rack in the ice. Using a new sterile loop, repeat for the -J45200 tube.<br>
+
5. Use a sterile loop to pick up a single colony of bacteria from the BBa_J45999 starter plate. Pick up the +J45200 tube and immerse the loop in the transformation solution at the bottom of the tube. Spin the loop between your index finger and thumb until the entire colony is dispersed in the transformation solution (with no floating chunks). Place the tubes back in the tube rack in the ice. Using a new sterile loop, repeat for the -J45200 tube.<br>
-
6. Immerse a new sterile loop into the stock tube containing the re-suspended J45200 plasmid. Withdraw a loopful.<br> There should be a film of plasmid solution across the ring. Mix the loopful into the cell suspension of the +J45200 tube. Close the tube and return it to the rack on ice. Also close the -J45200 tube. Do not add plasmid DNA to the -J45200. <br>
+
6. Immerse a new sterile loop into the stock tube containing the re-suspended J45200 plasmid. Withdraw a loopful which is approximately 10μl of DNA.<br> There should be a film of plasmid solution across the ring. Mix the loopful into the cell suspension of the +J45200 tube. Close the tube and return it to the rack on ice. Also close the -J45200 tube. Do not add plasmid DNA to the -J45200. <br>
-
7. Incubate the tubes on ice for 10 minutes. Make sure to push the tube all the way down in the rack so the bottoms of the tubes stick out and make contact with the ice. <br>
+
7. Repeat for NEB 10-beta cells.
-
8. While the tubes are sitting on ice, label your four LB nutrient agar plates on the bottom sides as follows:<br>
+
-
LB/amp +<br>
+
-
LB/amp –<br>
+
-
LB +<br>
+
-
LB -<br>
+
-
9. Using the foam rack as a holder, transfer both the +J45200 and -J45200 tubes into the water bath set at 42 degrees Celsius, for exactly 50 seconds. Make sure to push the tubes all the way down in the rack so the bottoms of the tubes stick out and make contact with the warm water.<br>
+
-
10. Directly after the 50 seconds, place both tubes back on ice (0° C). Incubate the tubes on ice for 2 minutes.<br>
+
-
11.  Remove the rack containing the tubes from the ice and place on the bench top. Open a tube and, using a new sterile pipet, add 250 microliters of LB nutrient broth to the tube and reclose it. Repeat with a new sterile pipet for the other tube. Incubate the tubes for 10 minutes at room temperature.<br>
+
-
12. Tap the closed tubes with your finger to mix. Pipet 100 microliters of the transformation suspension (+J45200) onto the LB/amp + plate using a new sterile pipet. Pipet 100 microliters of the control suspension (-J45200) onto the LB/amp – plate, using a new sterile pipet.<br>
+
-
13. Spread the suspensions evenly around the surface of the agar using the flat surface of a sterile loop. Use a new sterile loop for each plate.<br>
+
-
14. Stack up your plates and tape them together. Put the stack upside down in the incubator at 37°C until the next day.
+
-
<U>Transformation of Second Plasmid</U><br>
+
8. Incubate the tubes on ice for 10 minutes. Make sure to push the tube all the way down in the rack so the bottoms of the tubes stick out and make contact with the ice. <br>
 +
9. While the tubes are sitting on ice, label your 6 LB nutrient agar plates on the bottom sides as follows:<br>
 +
<center>LB/amp (+) BBBa_J45999                              <br>        
 +
LB/amp (–) BBa_J45999                                                          <br>      
 +
LB (-) BBa_J45999                     
-
A. Make competent cells<br>
+
LB/amp (+) NEB 10-beta<br>   
-
1. Remove transformation plate LB/amp + from the incubator or fridge.<br>
+
LB/amp (–) NEB 10-beta<br>                 
-
2. Label one 0.6ml tube with "NEB 10-beta 2" and add 100ul of distilled water to it.<br>
+
LB (-) NEB 10-beta</center><br>                         
-
3. Use an inoculating loop, or pipette tip, to pick a single colony from the LB/amp + plate and inoculate the distilled water.<br>
+
10. Using the foam rack as a holder, transfer the +J45200 and -J45200 tubes into the water bath set at 42 degrees Celsius, for exactly 90 seconds. Make sure to push the tubes all the way down in the rack so the bottoms of the tubes stick out and make contact with the warm water.<br>
-
4. Pipette up and down to re-suspend the colony into the distilled water, and transfer to the fresh SOB agar plate.<br>
+
11. Directly after the 90 seconds, place both tubes back on ice (0° C). Incubate the tubes on ice for 2 minutes.<br>
 +
12.  Remove the rack containing the tubes from the ice and place on the bench top. Open a tube and, using a new sterile pipet, add 250 μl of LB nutrient broth to the tube and reclose it. Repeat with a new sterile pipet for the other tube. Incubate the tubes for 10 minutes at room temperature.<br>
 +
13. Tap the closed tubes with your finger to mix. Pipet 100 μl of the transformation suspension (+J45200 for BBBa_J45999) onto the LB/amp + plate using a new sterile pipet. Pipet 100 μl of the control suspension (-J45200) onto the LB/amp – plate, using a new sterile pipet. Pipet 100 μl of the control suspension (-J45200) onto the LB – plate, using a new sterile pipet.  Repeat for NEB 10-beta cells.<br>
 +
14. Spread the suspensions evenly around the surface of the agar using the flat surface of a sterile loop. Use a new sterile loop for each plate.<br>
 +
15. Stack up your plates and tape them together. Put the stack upside down in the incubator at 37°C until the next day.
 +
 
 +
<b>Transformation of Plasmid 2 (BBa_K145201)</b><br>
 +
 
 +
<u>Make competent cells</u><br>
 +
1. Remove transformation plate LB/amp (+) BBa_J45999 and LB/amp (+) NEB 10-beta from the incubator or fridge.<br>
 +
2. Label one microtube with "NEB 10-beta 2" and one microtube "BBa_J45999" and add 100ul of distilled water to each.<br>
 +
3. Use an inoculating loop, or pipette tip, to pick a single colony from the LB/amp + plate and inoculate the distilled water for each cell type.<br>
 +
4. Pipette up and down to re-suspend the colony into the distilled water, and transfer to the fresh LB/amp agar plates.<br>
5. Spread the cells across the plate using either an inoculating loop, or by pouring 3-6 glass beads into the plate, covering, and shaking from side to side.<br>
5. Spread the cells across the plate using either an inoculating loop, or by pouring 3-6 glass beads into the plate, covering, and shaking from side to side.<br>
-
6. Place the SOB agar plate into the incubator with the agar side facing up, lid facing down (see picture below). Incubate the plate at 37°C for 14-16 hours. Alternately, incubate at room temperature for 24-30 hours.<br>
+
6. Place the LB/amp agar plate into the incubator with the agar side facing up, lid facing down (see picture below). Incubate the plate at 37°C for 14-16 hours. Alternately, incubate at room temperature for 24-30 hours.<br>
7. Once your agar plate has grown up you can store it in your fridge (4°C) until you're ready to make competent cells.
7. Once your agar plate has grown up you can store it in your fridge (4°C) until you're ready to make competent cells.
-
B. Re-suspending<br>
+
<u>Re-suspending</U><br>
1. Use a pipette to re-suspend part K145201 with 10 microliters of distilled water. Aspirate up and down a few times to ensure the DNA has been fully re-suspended.  
1. Use a pipette to re-suspend part K145201 with 10 microliters of distilled water. Aspirate up and down a few times to ensure the DNA has been fully re-suspended.  
-
C. Transformation<br>
+
<u>Transformation</u><br>
-
1. Remove plate from the incubator. This plate is the LB/amp + sample used to make competent cells.<br>
+
1. Remove plates from the incubator. These plates are LB/amp (+) BBa_J45999 and LB/amp (+) NEB 10-beta produced from the previous transformation.<br>
-
2. Label one tube +K145201/J45200 and one tube +J45200.<br>
+
2. Label one tube +K145201/+J45200 BBa_J45999 and one tube -K145201/+J45200 BBa_J45999.  Label one more tube +K145201/+J45200 NEB10 and one -K145201/+J45200 NEB10.<br>
3. Open the tubes and, using a sterile transfer pipet, transfer 250 microliters of transformation solution (CaCl2).<br>
3. Open the tubes and, using a sterile transfer pipet, transfer 250 microliters of transformation solution (CaCl2).<br>
4. Place the tubes on ice.<br>
4. Place the tubes on ice.<br>
-
5. Use a sterile loop to pick up a single colony of bacteria from the LB/amp + competent cells plate. Pick up the +K145201 and immerse the loop in the transformation solution at the bottom of the tube. Spin the loop between your index finger and thumb until the entire colony is dispersed in the transformation solution (with no floating chunks). Place the tubes back in the tube rack in the ice. Using a new sterile loop, repeat for the +J45200 tube.<br>
+
5. Use a sterile loop to pick up a single colony of bacteria from the LB/amp (+) BBa_J45999 competent cells plate. Pick up the +K145201/+J45200 BBa_J45999 tube and immerse the loop in the transformation solution at the bottom of the tube. Spin the loop between your index finger and thumb until the entire colony is dispersed in the transformation solution (with no floating chunks). Place the tubes back in the tube rack in the ice. Using a new sterile loop, repeat for the -K145201/+J45200 BBa_J45999 tube.<br>
-
6. Immerse a new sterile loop into the stock tube containing the re-suspending K145201 plasmid. Withdraw a loopful. There should be a film of plasmid solution across the ring. Mix the loopful into the cell suspension of the +K145201/J45200 tube. Close the tube and return it to the rack on ice. Also close the +J45200 tube. Do not add plasmid DNA to the -J45200.<br>
+
6. Immerse a new sterile loop into the stock tube containing the re-suspending K145201 plasmid. Withdraw a loopful. There should be a film of plasmid solution across the ring. Mix the loopful into the cell suspension of the +K145201/+J45200 BBa_J45999 tube. Close the tube and return it to the rack on ice. Also close the -K145201/+J45200 BBa_J45999 tube. Do not add plasmid DNA to this tube. Repeat for LB/amp (+) NEB 10-beta cells.<br>  
7. Incubate the tubes on ice for 10 minutes. Make sure to push the tube all the way down in the rack so the bottoms of the tubes stick out and make contact with the ice.<br>  
7. Incubate the tubes on ice for 10 minutes. Make sure to push the tube all the way down in the rack so the bottoms of the tubes stick out and make contact with the ice.<br>  
8. While the tubes are sitting on ice, label your LB nutrient agar plates on the bottom sides as follows:<br>
8. While the tubes are sitting on ice, label your LB nutrient agar plates on the bottom sides as follows:<br>
-
LB/amp/kan +<br>
+
 
-
LB/amp +<br>
+
<center>LB/amp/kan (+) BBa_J45999 <br>
-
LB +<br>
+
LB/amp/kan (-) BBa_J45999 <br>
-
LB <br>
+
LB (–) BBa_J45999 <br>
-
9. Using the foam rack as a holder, transfer the three tubes into the water bath set at 42° C, for exactly 50 seconds. Make sure to push the tubes all the way down in the rack so the bottoms of the tubes stick out and make contact with the warm water.<br>
+
 
-
10. Directly after the 50 seconds, place all three tubes back on ice (0° C). Incubate the tubes on ice for 2 minutes.<br>
+
LB/amp/kan (+) NEB10 <br>
 +
LB/amp/kan (-) NEB10 <br>
 +
LB (–) NEB10 </center>
 +
9. Using the foam rack as a holder, transfer the three tubes into the water bath set at 42° C, for exactly 90 seconds. Make sure to push the tubes all the way down in the rack so the bottoms of the tubes stick out and make contact with the warm water.<br>
 +
10. Directly after the 90 seconds, place all three tubes back on ice (0° C). Incubate the tubes on ice for 2 minutes.<br>
11.  Remove the rack containing the tubes from the ice and place on the bench top. Open a tube and, using a new sterile pipet, add 250 microliters of LB nutrient broth to the tube and reclose it. Repeat with a new sterile pipet for the other two tubes. Incubate the tubes for 10 minutes at room temperature.<br>
11.  Remove the rack containing the tubes from the ice and place on the bench top. Open a tube and, using a new sterile pipet, add 250 microliters of LB nutrient broth to the tube and reclose it. Repeat with a new sterile pipet for the other two tubes. Incubate the tubes for 10 minutes at room temperature.<br>
12. Tap the closed tubes with your finger to mix. <br>
12. Tap the closed tubes with your finger to mix. <br>
-
13. Pipet 100 microliters of the transformation suspension +K145201/J45200 onto the LB/amp/kan + using a new sterile pipet. Repeat this step, using new sterile pipets, for the LB+ and LB- plates.<br>
+
13. Pipet 100 microliters of the transformation suspension +K145201/+J45200 onto the LB/amp/kan (+) BBa_J45999 plate. Repeat this step by pipetting 100 μl of the -K145201/+J45200 BBa_J45999 onto the LB/amp/kan (-) BBa_J45999 and LB (-) BBa_J45999 plates.
-
14. Pipet 100 microliters of the transformation suspension +J45200 onto the LB/amp + using a new sterile pipet. Repeat this step, using new sterile pipets, for the LB+ and LB- plates.<br>
+
14. Spread the suspensions evenly around the surface of the agar using the flat surface of a sterile loop. Use a new sterile loop for each plate.<br>
-
15. Spread the suspensions evenly around the surface of the agar using the flat surface of a sterile loop. Use a new sterile loop for each plate.<br>
+
15. Stack up your plates and tape them together. Put the stack upside down in the incubator at 37°C until the next day.
-
16. Stack up your plates and tape them together. Put the stack upside down in the incubator at 37°C until the next day.
+
== <B>Circuit 2: Carbon Monoxide Detector</B> ==
== <B>Circuit 2: Carbon Monoxide Detector</B> ==
Line 420: Line 425:
2. 3A Assembly would be used to ligate <b>BBa_K352003</b> and <b>BBa_J45199</b> to produce the second plasmid in our CO detector system.   
2. 3A Assembly would be used to ligate <b>BBa_K352003</b> and <b>BBa_J45199</b> to produce the second plasmid in our CO detector system.   
-
<center>Refer to http://partsregistry.org/Help:3A_Assembly_Kit</center>
+
<center>Refer to [http://partsregistry.org/Help:3A_Assembly_Kit 3A Assembly Kit] at the Registry for details on this protocol.</center>
 +
 
 +
3. The transformation protocol outlined under [https://2012hs.igem.org/Team:Tyngsboro_MA_Tigers/Results#Circuit_1:_Proof_of_Concept Proof of Concept] would be used to produce the functional system described under [https://2012hs.igem.org/Team:Tyngsboro_MA_Tigers/Project Our Project] .
 +
 
 +
== <B>Results and Progress in Constructing a Working '''E. ([[CO]])'''[[factory]]</B> ==
 +
At present, we are performing experiments to investigate the efficiency of pUC19 which have thus far, generated inconclusive results. 
 +
 
 +
Next week we hope to initiate <b>Circuit 1</b> production to demonstrate the viability of our Proof of Concept. 
 +
 
 +
It is unlikely that <b>Circuit 2 </b>will be constructed due to our time and budget constraints.
-
3. The transformation protocol outlined under would be used to produce the functional system described under https://2012hs.igem.org/Team:Tyngsboro_MA_Tigers/Attributions#Attributions here] .
+
In both cases, characterization and optimization experiments will not be performed at this time.

Latest revision as of 01:26, 17 June 2012

Screen_shot_2012-06-14_at_10.38.23_PM.png

Contents

Results

Abstract

In the United States alone, carbon monoxide is responsible for over 2,100 deaths every year, with our only current defense being the warning sounds of carbon monoxide alarms. Carbon monoxide (CO) cannot be seen or smelled, so our project idea was to develop a biological alternative to the typical carbon monoxide detector to produce a warning smell, rather than a sound. Our circuit consists of the CO transcriptional activator CooA. In the presence of a CO inducer and an isoamyl alcohol precursor, the characteristic smell of bananas will be produced. Our team has developed a proof of concept circuit using the banana odor generating device as a reporter and the Tetracycline repressor as a constitutive generator to activate the transcription of ATF1 in an indole-free chassis. This circuit will replace CO gas with doxycycline as an inducer and isoamyl alcohol as a precursor to generate the banana smell.

pUC 19 Transformation

The goal: Perform a transformation using pUC19, a plasmid with high transformation efficiency, to test the quality of our protocol before using it for our experimental transformation.

The hypothesis: If the pUC19 transformed successfully into E. coli, then only those cells will grow on ampicillin plates because they contain an ampicillin resistance chain.

The results: The plate was covered in bacteria on both pUC19 side and NO DNA side. Results for this preliminary test are presently inconclusive.


Expected Results

Resultsexpected.png

This plate shows the expected results for the transformation:

The pUC19 side has bacteria growth and the No DNA side has no growth.


Materials

Making patches from agar stabs:

70% ethanol
paper towels
marker/Sharpie
Agar Stab: BBa_J45999
inoculating loops
(2) LB agar plates


Transformation(s)
Agar plate: Part A – BBa_J45999 patches
2μl pUC19 Eppendorf tubes ice
container for ice
timer
(2) 2.0ml microcentrifuge tubes
CaCl2 solution
inoculating loops
500μl LB Broth
(1) LB agar plates
(1) LB/amp agar plate
waterbath
thermometer


PROTOCOL

Preparing cell patches

1. Use a sterile inoculating loop to collect a sample of BBa_J45999 from the stab. 2. Streak 1 LB agar plate with this sample. 3. Grow overnight in 37°C incubator. 4. The next day, use a sterile inoculating loop to pick one colony and streak a square patch on a second LB agar plate. 5. Repeat so there are 3 patches. 6. Grow overnight in 37°C incubator.


Performing the Transformation

Part One
1. Label 2 small Eppendorf tubes with “pUC19” and “No DNA.”
2. Pipet 200 μl of CaCl2 transformation solution into each Eppendorf tube and then place them on ice.
3. Use a sterile inoculating loop to gently scrape up one entire patch of the indole free cells and then swirl the cells into the “puUC19” tube of cold CaCl2. Repeat the step for the “No DNA” tube of cold CaCl2.
4. Gently flick and invert the eppendorf tube to re-suspend the cells.
5. Keep competent cells on ice while you prepare the DNA for transformation.


Part Two
1. Retrieve the pUC19 sample from the freezer.
2. Add 2 μl of pUC19 into the tube labeled “pUC 19”. Flick to mix the tube and return it to ice. Do not add pUC19 to the tube labeled “No DNA."
3. Let the DNA and the cells sit on ice for 5 minutes.
4. While the cells are incubating, take a marker and label the bottom of the LB and ampicillin agar petri dish. Draw a line through the middle and label one side “pUC19” and the other side “No DNA”, then add the date.
5. Heat shock both samples by placing the tubes at 42°C for 90 seconds exactly.
6. At the end of the 90 seconds, move the tubes to a rack at room temperature.
7. Add .5 ml of room temperature LB to the tubes. Close the caps and invert the tubes to mix the contents.
8. Using a sterile spreader, spread 250 μl of the “pUC19” solution onto the designated half of the petri dish.
9. Using a new sterile spreader, spread 250 μl of the “No DNA” solution onto the designated half of the petri dish.
10. Cover the plate and set it aside for a minute, then turn the plate over.
11. Incubate the petri dish upside down overnight at 37°C.


Pictures from performing different steps of the pUC19 transformation

Step 1: Pipeting CaCl2 (transformation solution) into both test tubes.

Step 2: Keeping the samples on ice.

Step 3: Scraping a patch of indole free cells.

Step 4: Adding the cells to the samples.

Step 5: Re-suspending the cells in the sample.

Step 6: Labeling the agar plate with a pUC19 and No DNA side.

Step 7: Heat shocking the samples for 90 seconds at 42 degrees C.

Step 8: Spreading the samples onto the plates.

Pucpics.png


Results From First Trial


Resultsfirstplate2.jpg

The plate was covered in bacteria on both sides after just 24 hours of incubation.


Results From Second Trial


Results2ndplate.png

The plate was also covered in bacteria on both sides after just 24 hours of incubation.

If colonies form, we will use the following procedure to determine the transformation efficiency of the plasmid.


Determining Transformation Efficiency

Transformation efficiency = Total number of cells growing on the agar plate/Amount of DNA spread on the agar plate (in μg)

Refer to [http://www.bio-rad.com/LifeScience/pdf/Bulletin_9563.pdf BioRad] for protocol details.

Circuit 1: Proof of Concept

Once the transformation efficiency has been determined for pUC19, the transformation protocol will be repeated for BBa_J45200 (on ampicillin backbone). The transformants of this process will be used in a second transformation for BBa_K145201 (on kanamycin backbone). Colonies that grow on kan/amp agar plates will be selected for testing our proof of concept.

Materials

Streaking from agar stabs:
70% ethanol
paper towels
marker/Sharpie
sterile inoculating loop
(1) LB/amp agar plate (1) LB/kan agar plate
(1) LB agar plate
LB agar plate of BBa_J45999 patches LB agar plate of NEB10 beta strain (control) patches (see procedure for making patches above)

Re-suspending DNA
Part BBa_J45200
Part BBa_K145201
Pipet
Distilled Water

Transformation(s)
ice
container for ice
timer
Agar stab BBa_J45999 Agar stab NEB10 beta strain (control cells)
2.0ml microcentrifuge tubes (kit)
CaCl2 solution (kit)
sterile inoculating loops (kit)
Part BBa_J45200
BBa_K145201
LB broth
LB agar plates (kit)
water bath
thermometer


Procedure

Streaking from agar stabs
1. Clean lab bench by wiping down with 70% ethanol and paper towels.
2. Label an LB agar plate Indole Free or BBa_J45999.
3. Label an LB agar plate with NEB 10-beta.
4. Use an inoculating loop to transfer some cells from the BBa_J45999 agar stab to the plate. There is a hole in each agar stab from where it was inoculated. Dip an inoculating loop into the stab at the same location, and streak the bacteria onto the agar plate in a zig-zag pattern. Using a fresh inoculating loop, streak onto the agar plate again creating a new zig-zag pattern that overlaps the first. This will help ensure that you will have single colonies to pick from. Streak gently, and try not to puncture the agar.
5. Repeat step 4 for the NEB 10-beta strain.
6. Place the agar plates into the incubator upside down at 37°C for 14-16 hours or room temperature for 24-30 hours.
7. After incubating they can be stored in a fridge at 4°C until a culture can be grown.

Transformation of Plasmid 1 (BBa_J45200)
Preparing BBa_J45999 and NEB 10-beta cells (competent cells)

1. Remove the agar plate for NEB 10-beta from the incubator or 4°C fridge.
2. Label one Eppendorf tube with "NEB 10-beta" and add 100ul of distilled water to it.
3. Use an inoculating loop, or pipette tip, to pick a single colony from the NEB 10-beta agar plate and inoculate the distilled water.
4. Pipette up and down to re-suspend the colony into the distilled water, and transfer to the fresh LB agar plate.
5. Spread the cells across the plate using either an inoculating loop, or by pouring 3-6 glass beads into the plate, covering, and shaking from side to side.
6. Place the LB agar plate into the incubator with the agar side facing up, lid facing down (see picture below). Incubate the plate at 37°C for 14-16 hours. Alternately, incubate at room temperature for 24-30 hours.
7. Once your agar plate has grown up you can store it in your fridge (4°C) until you're ready to make competent cells. 8. Repeat for BBa_J45999 cells.

Re-suspending
1. Use a pipette to re-suspend part J45200 with 10 μl of distilled water. Aspirate up and down a few times to ensure the DNA has been fully re-suspended.

Transformation
1. Obtain the prepared LB plates BBa_J45999 indole free chassis and NEB 10-beta prepared from the previous step.
2. Label one closed microtube +J45200 and another -J45200. Place them in the foam tube rack.
3. Open the tubes and, using a sterile transfer pipet, transfer 250 μl of transformation solution (CaCl2).
4. Place the tubes on ice.
5. Use a sterile loop to pick up a single colony of bacteria from the BBa_J45999 starter plate. Pick up the +J45200 tube and immerse the loop in the transformation solution at the bottom of the tube. Spin the loop between your index finger and thumb until the entire colony is dispersed in the transformation solution (with no floating chunks). Place the tubes back in the tube rack in the ice. Using a new sterile loop, repeat for the -J45200 tube.
6. Immerse a new sterile loop into the stock tube containing the re-suspended J45200 plasmid. Withdraw a loopful which is approximately 10μl of DNA.
There should be a film of plasmid solution across the ring. Mix the loopful into the cell suspension of the +J45200 tube. Close the tube and return it to the rack on ice. Also close the -J45200 tube. Do not add plasmid DNA to the -J45200.
7. Repeat for NEB 10-beta cells.

8. Incubate the tubes on ice for 10 minutes. Make sure to push the tube all the way down in the rack so the bottoms of the tubes stick out and make contact with the ice.
9. While the tubes are sitting on ice, label your 6 LB nutrient agar plates on the bottom sides as follows:

LB/amp (+) BBBa_J45999

LB/amp (–) BBa_J45999
LB (-) BBa_J45999

LB/amp (+) NEB 10-beta
LB/amp (–) NEB 10-beta

LB (-) NEB 10-beta

10. Using the foam rack as a holder, transfer the +J45200 and -J45200 tubes into the water bath set at 42 degrees Celsius, for exactly 90 seconds. Make sure to push the tubes all the way down in the rack so the bottoms of the tubes stick out and make contact with the warm water.
11. Directly after the 90 seconds, place both tubes back on ice (0° C). Incubate the tubes on ice for 2 minutes.
12. Remove the rack containing the tubes from the ice and place on the bench top. Open a tube and, using a new sterile pipet, add 250 μl of LB nutrient broth to the tube and reclose it. Repeat with a new sterile pipet for the other tube. Incubate the tubes for 10 minutes at room temperature.
13. Tap the closed tubes with your finger to mix. Pipet 100 μl of the transformation suspension (+J45200 for BBBa_J45999) onto the LB/amp + plate using a new sterile pipet. Pipet 100 μl of the control suspension (-J45200) onto the LB/amp – plate, using a new sterile pipet. Pipet 100 μl of the control suspension (-J45200) onto the LB – plate, using a new sterile pipet. Repeat for NEB 10-beta cells.
14. Spread the suspensions evenly around the surface of the agar using the flat surface of a sterile loop. Use a new sterile loop for each plate.
15. Stack up your plates and tape them together. Put the stack upside down in the incubator at 37°C until the next day.

Transformation of Plasmid 2 (BBa_K145201)

Make competent cells
1. Remove transformation plate LB/amp (+) BBa_J45999 and LB/amp (+) NEB 10-beta from the incubator or fridge.
2. Label one microtube with "NEB 10-beta 2" and one microtube "BBa_J45999" and add 100ul of distilled water to each.
3. Use an inoculating loop, or pipette tip, to pick a single colony from the LB/amp + plate and inoculate the distilled water for each cell type.
4. Pipette up and down to re-suspend the colony into the distilled water, and transfer to the fresh LB/amp agar plates.
5. Spread the cells across the plate using either an inoculating loop, or by pouring 3-6 glass beads into the plate, covering, and shaking from side to side.
6. Place the LB/amp agar plate into the incubator with the agar side facing up, lid facing down (see picture below). Incubate the plate at 37°C for 14-16 hours. Alternately, incubate at room temperature for 24-30 hours.
7. Once your agar plate has grown up you can store it in your fridge (4°C) until you're ready to make competent cells.

Re-suspending
1. Use a pipette to re-suspend part K145201 with 10 microliters of distilled water. Aspirate up and down a few times to ensure the DNA has been fully re-suspended.

Transformation
1. Remove plates from the incubator. These plates are LB/amp (+) BBa_J45999 and LB/amp (+) NEB 10-beta produced from the previous transformation.
2. Label one tube +K145201/+J45200 BBa_J45999 and one tube -K145201/+J45200 BBa_J45999. Label one more tube +K145201/+J45200 NEB10 and one -K145201/+J45200 NEB10.
3. Open the tubes and, using a sterile transfer pipet, transfer 250 microliters of transformation solution (CaCl2).
4. Place the tubes on ice.
5. Use a sterile loop to pick up a single colony of bacteria from the LB/amp (+) BBa_J45999 competent cells plate. Pick up the +K145201/+J45200 BBa_J45999 tube and immerse the loop in the transformation solution at the bottom of the tube. Spin the loop between your index finger and thumb until the entire colony is dispersed in the transformation solution (with no floating chunks). Place the tubes back in the tube rack in the ice. Using a new sterile loop, repeat for the -K145201/+J45200 BBa_J45999 tube.
6. Immerse a new sterile loop into the stock tube containing the re-suspending K145201 plasmid. Withdraw a loopful. There should be a film of plasmid solution across the ring. Mix the loopful into the cell suspension of the +K145201/+J45200 BBa_J45999 tube. Close the tube and return it to the rack on ice. Also close the -K145201/+J45200 BBa_J45999 tube. Do not add plasmid DNA to this tube. Repeat for LB/amp (+) NEB 10-beta cells.
7. Incubate the tubes on ice for 10 minutes. Make sure to push the tube all the way down in the rack so the bottoms of the tubes stick out and make contact with the ice.
8. While the tubes are sitting on ice, label your LB nutrient agar plates on the bottom sides as follows:

LB/amp/kan (+) BBa_J45999

LB/amp/kan (-) BBa_J45999
LB (–) BBa_J45999

LB/amp/kan (+) NEB10
LB/amp/kan (-) NEB10

LB (–) NEB10

9. Using the foam rack as a holder, transfer the three tubes into the water bath set at 42° C, for exactly 90 seconds. Make sure to push the tubes all the way down in the rack so the bottoms of the tubes stick out and make contact with the warm water.
10. Directly after the 90 seconds, place all three tubes back on ice (0° C). Incubate the tubes on ice for 2 minutes.
11. Remove the rack containing the tubes from the ice and place on the bench top. Open a tube and, using a new sterile pipet, add 250 microliters of LB nutrient broth to the tube and reclose it. Repeat with a new sterile pipet for the other two tubes. Incubate the tubes for 10 minutes at room temperature.
12. Tap the closed tubes with your finger to mix.
13. Pipet 100 microliters of the transformation suspension +K145201/+J45200 onto the LB/amp/kan (+) BBa_J45999 plate. Repeat this step by pipetting 100 μl of the -K145201/+J45200 BBa_J45999 onto the LB/amp/kan (-) BBa_J45999 and LB (-) BBa_J45999 plates. 14. Spread the suspensions evenly around the surface of the agar using the flat surface of a sterile loop. Use a new sterile loop for each plate.
15. Stack up your plates and tape them together. Put the stack upside down in the incubator at 37°C until the next day.

Circuit 2: Carbon Monoxide Detector

1. The first plasmid, BBa_352015 will have to be built from individual parts obtained from the Parts Registry since it is not available in the Parts Registry at this time.

2. 3A Assembly would be used to ligate BBa_K352003 and BBa_J45199 to produce the second plasmid in our CO detector system.

Refer to [http://partsregistry.org/Help:3A_Assembly_Kit 3A Assembly Kit] at the Registry for details on this protocol.

3. The transformation protocol outlined under Proof of Concept would be used to produce the functional system described under Our Project .

Results and Progress in Constructing a Working E. (CO)factory

At present, we are performing experiments to investigate the efficiency of pUC19 which have thus far, generated inconclusive results.

Next week we hope to initiate Circuit 1 production to demonstrate the viability of our Proof of Concept.

It is unlikely that Circuit 2 will be constructed due to our time and budget constraints.

In both cases, characterization and optimization experiments will not be performed at this time.