<li>3. Using a 10 μl micropipette, take a white tip and drill the aluminum cover in the well where is located the BioBrick piece. </li> | <li>3. Using a 10 μl micropipette, take a white tip and drill the aluminum cover in the well where is located the BioBrick piece. </li> | ||
<li>4. Using the same micropipette, throw away the tip, take another one to take 10 μl of mQ water and introduce this tip in the well. </li> | <li>4. Using the same micropipette, throw away the tip, take another one to take 10 μl of mQ water and introduce this tip in the well. </li> | ||
- | <li>5. Up and down the liquid using the micropipette a couple of times until the DNA is completely resuspended (when dissolving the DNA, it will give to the water a reddish coloration, so, the more reddish the solution means that the resuspension was well done. </li> | + | <li>5. Up and down the liquid using the micropipette a couple of times until the DNA is completely resuspended (when dissolving the DNA, it will give to the water a reddish coloration, so, the more reddish the solution means that the resuspension was well done.)</li> |
<li>6. Pour the liquid in a 0.6 μl centrifuge tube, label and store at -20°C. </li> | <li>6. Pour the liquid in a 0.6 μl centrifuge tube, label and store at -20°C. </li> | ||
</p> | </p> | ||
Line 496: | Line 496: | ||
<p><li>1.Add the correct antibiotic to a test tube with culture medium. </li> | <p><li>1.Add the correct antibiotic to a test tube with culture medium. </li> | ||
- | <li>2. | + | <li>2.Pick a colony with a bacteriological loop previously sterilized or pick with the point of the micropipette</li> |
<li>3.Shake by making small circles in the culture (if a handle was used) or up and down the culture a couple of times (if a micropipette was used).</li> | <li>3.Shake by making small circles in the culture (if a handle was used) or up and down the culture a couple of times (if a micropipette was used).</li> | ||
- | <li>4.Incubate at 37°C with vigorous and continuous agitation (250rpm) from 16 to 18 hours.</li></ | + | <li>4.Incubate at 37°C with vigorous and continuous agitation (250rpm) from 16 to 18 hours.</li></p> |
<div class="br"></div><div class="br"></div> | <div class="br"></div><div class="br"></div> | ||
<div class="br"></div><div class="br"></div> | <div class="br"></div><div class="br"></div> | ||
Line 509: | Line 509: | ||
<li>2.Take approx. 20 μL of culture containing bacteria and introduce them into a test tube with the new culture medium.</li> | <li>2.Take approx. 20 μL of culture containing bacteria and introduce them into a test tube with the new culture medium.</li> | ||
<li>3.Incubate at 37°C with vigorous and continuous agitation (250 rpm) from 16 to 18 hours.</li></p> | <li>3.Incubate at 37°C with vigorous and continuous agitation (250 rpm) from 16 to 18 hours.</li></p> | ||
- | |||
<div class="br"></div><div class="br"></div> | <div class="br"></div><div class="br"></div> | ||
<div class="br"></div><div class="br"></div> | <div class="br"></div><div class="br"></div> |
Latest revision as of 22:34, 16 June 2012
Lab Protocols
Use of plates with BioBrick lyophilazed