Team:AUC Turkey/Procedures
From 2012hs.igem.org
(Difference between revisions)
(→Procedures for LB Broth Preparation) |
(Undo revision 10366 by Alihancelikcan (talk)) |
||
(4 intermediate revisions not shown) | |||
Line 1: | Line 1: | ||
{{AUC_Turkey}} | {{AUC_Turkey}} | ||
+ | |||
+ | == Procedures for LB Agar Preparation == | ||
+ | |||
+ | *In a steril enviroment, the tare of the container should be measured and subtracted from the overall weight. | ||
+ | *7 grams of LB Agar is put in the container. | ||
+ | *200 ml distilled water or is put into a graduated cylinder. | ||
+ | *These two are mixed in a beaker. | ||
+ | *The opening of the beaker is covered with aliminium folio in such a way that it does not conctact with air. | ||
+ | *Autoclave tape is sticked on to the aliminium. | ||
+ | *The beaker is placed in to the autoclave machine. | ||
+ | *Distilled water or demineralized water is put into the autoclave machine. The water level in the autoclave machine has to be a little higher than the liquid level of the beaker. | ||
+ | *After closing the lid of the machine, the 90 minute autoclave process is given start. | ||
+ | *Take out the beaker and add antibiotics if required. | ||
+ | |||
+ | ''Warnings for the Autoclaw!'' | ||
+ | |||
+ | *Use only demineralised or disttiled water with the device. | ||
+ | *Do not open the cover until the manometer drops to zero during the operation. | ||
+ | *Please do not use the autoclave for other purposes than sterilization and agar. | ||
+ | *Please do not use the autoclave to sterilize explosive, inflammable and oxidizing materials. | ||
+ | *Please be cautious when you are closing the lid not to trap your hand. | ||
+ | *Please beware of the steam exhaust when you are opening to autoclave after sterilization. | ||
+ | *Please wear protective gloves before removibg materials from the chamber. Do not access the chamber unless the vapor exhaust is finalized. | ||
+ | |||
+ | |||
== Procedures for LB Broth Preparation == | == Procedures for LB Broth Preparation == | ||
Line 81: | Line 106: | ||
== Gel Preparation == | == Gel Preparation == | ||
- | + | *Mix 100ml TAE and 0,8 gram agarose in a glass beaker. | |
- | Mix 100ml TAE and 0,8 gram agarose in a glass beaker. | + | *The mixture is then heated in a microwave for 3 minutes. |
- | + | *Afterwards, 3,6 ul EtBr is added and the beaker is mixed on a magnetic mixer. | |
- | The mixture is then heated in a microwave for 3 minutes. | + | *Mold them and wait for 20 minutes fort he gel to harden. |
- | + | ||
- | Afterwards, 3,6 ul EtBr is added and the beaker is mixed on a magnetic mixer. | + | |
- | + | ||
- | Mold them and wait for 20 minutes fort he gel to harden. | + | |
- | + | ||
== Electrophoresis Protocol == | == Electrophoresis Protocol == | ||
- | Put 3 ul coloring agent on a strand of parafilm. | + | *Put 3 ul coloring agent on a strand of parafilm. |
- | + | *Take 7 ul plasmid and do pipeting with the colouring agent. | |
- | Take 7 ul plasmid and do pipeting with the colouring agent. | + | *Switch the pipette to 10 ul and take the colored plasmid. |
- | + | *Place the plasmid into one of the holes of our gel. | |
- | Switch the pipette to 10 ul and take the colored plasmid. | + | *Give electricity to the anode and cathode in required amounts. |
- | + | *Wait according to the tank and the amount of electricity. | |
- | Place the plasmid into one of the holes of our gel. | + | *Use the UV camera to get the results. |
- | + | ||
- | Give electricity to the anode and cathode in required amounts. | + | |
- | + | ||
- | Wait according to the tank and the amount of electricity. | + | |
- | + | ||
- | Use the camera to get the results. | + | |
- | + | ||
- | + | ||
<forum_subtle/> | <forum_subtle/> |
Latest revision as of 12:58, 20 March 2013
Sponsors | ||
---|---|---|
|
Procedures for LB Agar Preparation
- In a steril enviroment, the tare of the container should be measured and subtracted from the overall weight.
- 7 grams of LB Agar is put in the container.
- 200 ml distilled water or is put into a graduated cylinder.
- These two are mixed in a beaker.
- The opening of the beaker is covered with aliminium folio in such a way that it does not conctact with air.
- Autoclave tape is sticked on to the aliminium.
- The beaker is placed in to the autoclave machine.
- Distilled water or demineralized water is put into the autoclave machine. The water level in the autoclave machine has to be a little higher than the liquid level of the beaker.
- After closing the lid of the machine, the 90 minute autoclave process is given start.
- Take out the beaker and add antibiotics if required.
Warnings for the Autoclaw!
- Use only demineralised or disttiled water with the device.
- Do not open the cover until the manometer drops to zero during the operation.
- Please do not use the autoclave for other purposes than sterilization and agar.
- Please do not use the autoclave to sterilize explosive, inflammable and oxidizing materials.
- Please be cautious when you are closing the lid not to trap your hand.
- Please beware of the steam exhaust when you are opening to autoclave after sterilization.
- Please wear protective gloves before removibg materials from the chamber. Do not access the chamber unless the vapor exhaust is finalized.
Procedures for LB Broth Preparation
- In a steril enviroment, the tare of the container should be measured and subtracted from the overall weight.
- 7 grams of LB Broth is put in the container.
- 200 ml distilled water or is put into a graduated cylinder.
- These two are mixed in a beaker.
- The opening of the beaker is covered with aliminium folio in such a way that it does not conctact with air.
- Autoclave tape is sticked on to the aliminium.
- The beaker is placed in to the autoclave machine.
- Distilled water or demineralized water is put into the autoclave machine. The water level in the autoclave machine has to be a little higher than the liquid level of the beaker.
- After closing the lid of the machine, the 90 minute autoclave process is given start.
- Take out the beaker and add antibiotics if required.
Warnings for the Autoclave!
- Use only demineralised or disttiled water with the device.
- Do not open the cover until the manometer drops to zero during the operation.
- Please do not use the autoclave for other purposes than sterilization and agar.
- Please do not use the autoclave to sterilize explosive, inflammable and oxidizing materials.
- Please be cautious when you are closing the lid not to trap your hand.
- Please beware of the steam exhaust when you are opening to autoclave after sterilization.
- Please wear protective gloves before removibg materials from the chamber. Do not access the chamber unless the vapor exhaust is finalized.
Procedures for Transformation
- Transfer 500 ul LB Broth to 1.5 ml microcentrifuge tubes. This should be done close to a source of fire to prevent contamination.
- Place the microcentrifuge tubes containing LB Broth in a 42 C heat block for incubation.
- Take 1 ul plasmid and place them in 1.5 ml centrifuge tubes.
- Add 50 ul competent cells to the plasmid.
- Centrifuge them at 3000 rpm for 20-30 seconds.
- Incubate the cells in ice for 45 minutes.
- After 45 minutes, heat the tubes in the 42 C heat block for a maximum of 90 seconds.
- The same tubes should be placed in ice and should be incubated for 5 minutes.
- Afterwards, 450 ul LB should be added to the cells to complete them to 500 ul.
- The microcentrifuge tubes are then sticked to the shaker horizantally and shaked for 1 hour with 320 rpm at 37 C.
- 150 ul of the mixture(200 ul for digestion) is then placed on the plate to spread.
- It is then spread on the plate and the plates are incubated at 37 C for 16 hours.
Procedures for Isolation
- The LB Media should be transferred to 1.5 ml centrifuge tubes.
- These tubes are then centrifuged at 13,000 rpm for 10 minutes at room temperature.
- After the centrifuge, the supernatent should be disposed without taking any pellets along with it.
- The pelleted cells should be suspended in 250 ul Resuspension Solution and the tubes should be vortexed so that no cell clumps remain.
- 350 ul Neutralization Solution should be added and the tube should be inverted immediately and throughly by inverting 4-6 times.
- Centrifuge for 5 minutes to pellet cell debris and chromosomal DNA.
- Transfer the supernatent to a spin column without taking any of the pellets.
- Centrifuge the spin column for 1 minutes and discard the liquid at the bottom. Place the column at the same tube again.
- Add 500 ul Wash Solution and centrifuge for 30-60 seconds. Discard the flow-through and place column back in.
- Repeat the same process again with 500 ul Wash Solution.
- Centrifuge for an additional 1 minute.
- Transfer the columns into 1.5 ml microcentrifuge tubes and leave their caps open for 2 minutes so that the ethanol that they contain dissolves in air.
- Add 50 ul Elution Buffer to the center of the silica membrane to elute the plasmid DNA. The pipette tip shouldn't the membrane. Incubate for 2 minutes and centrifuge for 2 minutes afterwards.
- Discard the spin column and store at -20 C.
Digestion protocol
- Take the average of the nucleic acid concentrations measured by the spectrometer.
- Divide 500 by the DNA average.
- Add 5ul Ne Buffer.
- Add 0.5ul BSA Buffer.
- Add 1 ul of the enzymes with barrier tips.
- If you cut with EcoR1 and SpI, it will be up stream.
- If you cut with Xbal and Pst1, it will be down stream.
- Subtract the amount of DNA from 42.5 ul. This result will be the amount of NFW used.
- Add the NFW with barrier tips and do one pippetting while taking the NFW.
- Then the DNA is put into the PCR and is left there for 30 minutes.
Ligation protocol
- 2ul up stream is put into a eppendorf.
- 2ul down stream is also added.
- 2ul plasmid is mixed in as well.
- 2ul Taq Buffer is inserted to the mixture.
- 1ul T4 DNA ligase is then added with barrier tips.
- 11ul NFW is added with barrier tips and should be pipetted once.
- Then the DNA is put into the PCR and is left there for 30 minutes.
Gel Preparation
- Mix 100ml TAE and 0,8 gram agarose in a glass beaker.
- The mixture is then heated in a microwave for 3 minutes.
- Afterwards, 3,6 ul EtBr is added and the beaker is mixed on a magnetic mixer.
- Mold them and wait for 20 minutes fort he gel to harden.
Electrophoresis Protocol
- Put 3 ul coloring agent on a strand of parafilm.
- Take 7 ul plasmid and do pipeting with the colouring agent.
- Switch the pipette to 10 ul and take the colored plasmid.
- Place the plasmid into one of the holes of our gel.
- Give electricity to the anode and cathode in required amounts.
- Wait according to the tank and the amount of electricity.
- Use the UV camera to get the results.
<forum_subtle/>