Team:CIDEB-UANL Mexico/Project/Abstract

From 2012hs.igem.org

(Difference between revisions)
(Created page with "{{:Team:CIDEB-UANL_Mexico/Templates/Header}} {{:Team:CIDEB-UANL_Mexico/Templates/Menu}} {{:Team:CIDEB-UANL_Mexico/Templates/Style}} <html> <head> <!-- ========================...")
 
(8 intermediate revisions not shown)
Line 74: Line 74:
     <div id="leftColumn">
     <div id="leftColumn">
     <div id="ColorHeader">
     <div id="ColorHeader">
-
             Modelling
+
             Project: Abstract
     </div>
     </div>
Line 83: Line 83:
     <div id="header-project-column">
     <div id="header-project-column">
<div class="br2"></div><div class="br2"></div><div class="br2"></div>             
<div class="br2"></div><div class="br2"></div><div class="br2"></div>             
-
           <a name="Absract"></a>Abstract
+
           <a name="Project"></a>Abstract
<div class="br2"></div><div class="br2"></div>             
<div class="br2"></div><div class="br2"></div>             
       </div>
       </div>
<div class="br"></div><div class="br"></div>
<div class="br"></div><div class="br"></div>
-
     <p>Nowadays due to the contamination caused by pollutants such as heavy metals, it is important the implementation of simple and complete detection methods. This project aims to create a biosensor that may detect the presence of heavy metals in water. In order to construct the biosensor, a genetic circuit was built into E. coli. The circuit represents a model, which works with Arabinose. It is a semi-quantitative biosensor. The circuit has 3 parts: High concentration, Low concentration and Stand-by state. Each part of the circuit has a different response: when there is a high concentration of Arabinose the bacteria shows a yellow fluorescent color; when the concentration is low it uses a sensitivity tunner that increases the response from the same amount of Arabinose, which makes the bacteria to appear in a red fluorescence; and when there is no Arabinose in the sample, the bacteria shows a green fluorescence..</p>
+
     <p>Nowadays due to the contamination caused by pollutants such as heavy metals, it is important the implementation of simple and complete detection methods. This project aims to create a biosensor that may detect the presence of heavy metals in water. In order to construct the biosensor, a genetic circuit was built into E. coli. The circuit represents a model, which works with Arabinose. It is a semi-quantitative biosensor. The circuit has 3 parts: High concentration, Low concentration and Stand-by state. Each part of the circuit has a different response: when there is a high concentration of Arabinose the bacteria shows a yellow fluorescent color; when the concentration is low it uses a sensitivity tunner that increases the response from the same amount of Arabinose, which makes the bacteria to appear in a red fluorescence; and when there is no Arabinose in the sample, the bacteria shows a green fluorescence. </p>
-
<p>The effect of an inhibitor was modeled as follows:</p>
+
 +
<div class="br"></div>
 +
<div class="br"></div>
 +
<div class="br"></div>
 +
<div class="br"></div>
 +
 +
</div>
<div id="rightColumn">
<div id="rightColumn">
      
      
Line 103: Line 108:
     <div id="botonera">
     <div id="botonera">
-
    <div class="lateral-button"><a href="https://2011.igem.org/Team:UANL_Mty-Mexico/Modelling/Overview#Overview">Overview</a></div>
 
-
    <div class="lateral-button"><a href="https://2011.igem.org/Team:UANL_Mty-Mexico/Modelling/Overview#References">References</a></div>
 
    
    

Latest revision as of 04:30, 17 June 2012

banner-main iGEM-logo
Team: UANL_Mty-Mexico

Team: CIDEB-UANL Mexico

Project: Abstract
Abstract

Nowadays due to the contamination caused by pollutants such as heavy metals, it is important the implementation of simple and complete detection methods. This project aims to create a biosensor that may detect the presence of heavy metals in water. In order to construct the biosensor, a genetic circuit was built into E. coli. The circuit represents a model, which works with Arabinose. It is a semi-quantitative biosensor. The circuit has 3 parts: High concentration, Low concentration and Stand-by state. Each part of the circuit has a different response: when there is a high concentration of Arabinose the bacteria shows a yellow fluorescent color; when the concentration is low it uses a sensitivity tunner that increases the response from the same amount of Arabinose, which makes the bacteria to appear in a red fluorescence; and when there is no Arabinose in the sample, the bacteria shows a green fluorescence.

OurSymbol